ResMed’s ClimateLineAir Oxy Heated Tube for AirSense 10 and AirCurve 10 Machines features a small port on the cuff of the heated tube which allows the user to connect to supplemental oxygen.
Snap the cuff onto the AirSense 10 or AirCurve 10 outlet to experience Climate Control’s consistent warmth and humidity.
Climate Control
The Climate Control feature directly determines the temperature and humidity levels carried from the hose to the mask.
The hose receives the warmth and humidity provided by the Climate Control feature, which is built-in to the HumidAir humidifier.
The user can select between two options: Climate Control Auto or Climate Control Manual. The purpose of the feature is to increase the comfort of therapy.
The difference between the options is based on the dependence of Climate Control and Tube Temperature.
Climate Control Auto mode is recommended and is the default mode. Tube Temperature Auto and Climate Control Auto work in collaboration to prevent rainout and maintain moisture.
Tube temperature is set to 80 degrees F (27 degree C) in auto mode. The climate control feature then works dependent of the tube temperature to maintain a humidity of 85 percent.
Climate Control Auto will adjust the temperature of the air as it passes out of the humidifier in order to maintain humidity.
If the air feels too cold or too warm, the tube temperature can be set between 60 to 86 degree F (16 to 30 degree C), or the feature can be turned off completely.
In Climate Control Manual mode, the temperature in the tube is separate from the humidity. The user may adjust the temperature and the humidity without effecting the other component.
A potential drawback to the manual option is rainout. Without temperature and humidity working together, there is a greater chance for rainout.
If moisture begins to build in the hose, the user will need to begin troubleshooting the issue by adjusting the humidity levels.
Optional Humidity
Humidity is designed to relieve possible effects from sleep therapy. Moisture added to therapy may reduce dryness in the nasal passages and mouth.
Ultimately, humidity exists to provide comfort throughout the night.
Humidity Tips: To determine whether the humidity is too high or too low, look for the following indicators:
Increasing dry nose and mouth may imply the humidity level is not high enough. In this situation, raise the humidity level to decrease dryness.
Moisture building in the mask can be a sign of too much humidity. Reduce the humidity level to help minimize the moisture build-up.
To adjust the humidity levels on the HumidAir humidifier, select My Options and move the dial to select the ideal level.
Once the selection is determined, press the dial to secure the choice. The options range from Level 1 to Level 8 with Level 1 representing the lowest of the range.
If desired, the user may also select to turn the humidity off.
Includes-
- Heated Hose
Specifications
- Operating Temperature: +41 degree F to +95 degree F (+5 degree C to + 35 degree C)
- Operating Humidity:10% to 95% relative humidity, non-condensing
- Maximum Operating Altitude: 8,500 ft
- Storage and Transport Temperature: -4 degree F to +140 degree F (-20 degree C to +60 degree C)
- Storage and Transport Humidity: 5% to 95% relative humidity, non-condensing
- Temperature Range: +60 to +86 degree F (+16 to +30 degree C)
- Temperature Cutout: 106 degree F (+41 degree C)
- Maximum Recommended Pressure: 25cm H2O (25 hPa)
- Materials: Flexible plastic with electrical components
- Latex-Free: This product does not contain latex.
- Length: 6 ft 4 in (1.9 m)
- Inner Diameter: 0.75 in (19mm)
Cleaning Tips
For optimal performance, wash the tubing each week. Use warm water and mild shampoo to clean the tubing. Rinse well and allow it to dry away from sunlight.
It is safe to completely submerge the hose in water as long as it is completely dry before connecting it for use.
Please Note:
- The tubing is NOT intended to be cleaned in a dishwasher or washing machine. Also, this hose is NOT compatible with the 15mm or 19mm CPAP Tube Brush.
Product support
Warranty Policy
Review the general warranty periods for CPAP machines, masks, parts and accessories supplied by CPAPstudio.
The specific warranty period applicable to a product will normally be stated on the individual product page within the product description.
Where a specific warranty period is stated on the product page, that warranty period will apply to that product.
Where no specific warranty period is stated on the product page, the following general CPAPstudio warranty periods will apply:
On this page
General Warranty Periods
The following periods apply only where a different warranty period has not been specified on the individual product page.
| Product category | General warranty period | Coverage |
|---|---|---|
| New CPAP, APAP & BiPAP machines | 2 years | Manufacturing defects and functional faults during normal intended use. |
| Reconditioned / like-new CPAP, APAP & BiPAP machines | 6 months | Functional and manufacturing faults during normal intended use. |
| CPAP masks – complete mask systems | 3 months | Manufacturing defects only. |
| Mask frames | 3 months | Manufacturing defects only. |
| Mask cushions & nasal pillows | 3 months | Manufacturing defects only; normal deterioration is excluded. |
| Mask headgear & straps | 3 months | Manufacturing defects only; normal stretching and wear are excluded. |
| Standard & heated CPAP tubing | 3 months | Manufacturing defects only. |
| Humidifier water chambers / tubs | 3 months | Manufacturing defects only. |
| Separate / reusable humidifier units | 1 year | Manufacturing and functional defects. |
| CPAP batteries & battery packs | 6 months | Manufacturing defects and covered battery failure during normal use. |
| Power supplies & AC adapters | 2 years | Manufacturing and electrical defects during normal intended use. |
| Data modules & electronic accessories | 1 year | Manufacturing and functional defects. |
| Filters | 30 days | Manufacturing or supply defects only. |
| Other CPAP accessories & replacement parts | 3 months | Manufacturing defects only; normal deterioration is excluded. |
Important
The warranty periods shown in the table above are our general warranty periods and apply only where a different warranty period has not been specified on the individual product page.
If the product page states a different warranty period — whether shorter or longer — the warranty stated on the product page will apply, subject to your statutory consumer rights.
For example, if a particular CPAP machine is advertised with a 3-year warranty, that 3-year warranty will apply instead of the general 2-year period shown above.
Similarly, certain accessories, batteries or specialist products may have different warranty periods. Where this is the case, the applicable warranty will be clearly stated on the relevant product page.
Please check the warranty information in the product description before purchasing. If no specific warranty is shown, the general warranty periods in the table above will apply.
All warranty cover is provided in addition to your statutory consumer rights and does not exclude, restrict or replace those rights.
Contact Us
Have a question or need assistance? Our team is here to help with product enquiries, orders and support. Get in touch, and we'll be happy to assist you.
CPAPstudio – AA Sales Ltd
Unit B, 1, School Lane, Chandlers Ford, Eastleigh, Hampshire, SO53 4DG, United Kingdom
+44 (0) 7899 539620
We are here to help you! You can reach out to us via phone, email, or live chat. Our customer support team is available to assist you with any questions or concerns you may have. Phone and online chat hours: Monday – Friday, 9:00 AM – 4:00 PM; Saturday, 9:00 AM – 12:00 PM (UK time).
Our office is located at Unit B, 1 School Lane, Chandlers Ford, Eastleigh, SO53 4DG, United Kingdom. Visits are by appointment only, so please contact us at info@cpapstudio.co.uk or +44 7899 539620 to book a time.
We want you to be 100% satisfied with your purchase. Unopened Items can be returned or exchanged within 30 days of delivery.
Please contact our support team on chat, email or phone.
info@cpapstudio.co.uk
+44 7899 539620